Installation
X
Festo P.BE-CTEU-CO-OP+MAINT-EN en 1101NH
The following product and fieldbus-specific terms and abbre-
viations are used in this manual:
Term/abbreviation
Meaning
Bus nodes
create the connection to certain field busses/networks, pass on control
signals to the connected devices/modules and monitor their functioning.
COB-ID
Communication Object Identifiers consist of the function code and
address of the activated field bus slave (Node ID).
DCF
Device Configuration File = these files contain additional project data
which extends beyond EDS content/scope.
DIL switches
Dual-In-Line switches usually consist of several switching elements which
can be used to implement hardware settings.
EDS
Electronic Data Sheets include product-specific data about the bus node.
Fail state
This is a function which automatically activates the “Hold last state”
function in the event of an abortion of the network connection, and it is
also designated “fail safe” in some cases.
F0
h
Hexadecimal numbers are marked by a low-set “h”.
Heartbeat
The bus node sends a telegram cyclically to the network which can be
monitored by any station, compare with node guarding.
Hold last state
defines the status which outputs/valves are to assume after field bus
and/or communication errors
I/Os
Digital inputs and outputs
Load voltage
includes the power supply for connected devices and (digital) outputs,
e. g. solenoid coils of valves
Node guarding
Cyclic monitoring of the fieldbus station by the master controller by
requesting a response within a specified time period.
Node ID
Address of the fieldbus station
OB
Output byte
Object Directory
makes all important slave parameters accessible in a standardised
manner
O, I
Digital output, digital input
Summary of Contents for CTEU-CO
Page 2: ......
Page 14: ...Installation XII Festo P BE CTEU CO OP MAINT EN en 1101NH ...
Page 15: ...Commissioning 1 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Chapter 1 Commissioning ...
Page 37: ...Diagnosis 2 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Chapter 2 Diagnosis ...
Page 51: ...Error treatment 3 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Chapter 3 Error treatment ...
Page 58: ...3 Error treatment 3 8 Festo P BE CTEU CO OP MAINT EN en 1101NH ...
Page 59: ...Technical appendix A 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Appendix A Technical appendix ...
Page 74: ...A Technical appendix A 16 Festo P BE CTEU CO OP MAINT EN en 1101NH ...
Page 75: ...Index B 1 Festo P BE CTEU CO OP MAINT EN en 1101NH Appendix B Index ...