MAINTENANCE
Cleaning Condenser Coil (All Self Contained Refrigerated Units)
NOTICE:
Condenser coil must be cleaned a minimum of twice per month to insure
proper refrigeration performance and prevent compressor failure.
Failure to clean condenser coil will void condenser warranty.
VACUUM FRONT
SURFACE OF
CONDENSER COIL
FRONT PANEL
VACUUM FRONT
SURFACE OF
CONDENSER COIL
BACK PANEL
FLOOR BASE ITR MODEL
VACUUM FRONT
SURFACE OF
CONDENSER COIL
FRONT PANEL
VACUUM FRONT
SURFACE OF
CONDENSER COIL
BACK PANELS
COUNTER ITR MODEL
It is very important that the Condenser coil is cleaned twice per month to insure proper refrigeration
performance and to prevent compressor failure. Failure to clean condenser coil will void condenser
warranty.
The condenser can be cleaned from either the front or the back of case depending on which is more
accessible.
1.
Disconnect power to the unit.
2.
Remove the back or front panels located on the base or condenser compartment of unit. See Panel
Removal section of this manual.
3.
Carefully vacuum the front surface of condenser coil. Take care not to bend coil fins with vacuum
cleaner nozzle.
4.
Reinstall all panel and retaining screws and reconnect power.