INSTALLATION INSTRUCTIONS COUNTER MODELS
Inspection for Shipping Damage
You are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates
for damage as soon as they arrive. If damage is noted to shipping crates, cartons, or if a shortage is found,
note this on the bill of lading (all copies) prior to signing.
Locating Display Case
The counter units are designed to be placed on or into the top of a cabinet counter. The cabinet that the case
is to be used with must be located where it is not subjected to the direct rays of the sun, heating ducts,
grills, radiator, or ceiling fans, nor should it be located near open doors or main door entrances. Also,
avoid locations where there are excessive air movement or air disturbances.
The refrigerated cases require special consideration of cabinet design to allow condenser air to enter intake
and discharge from cabinet space. The requirements for specific cases outlined in this section must be
followed. Failure to follow these instructions will void warranty.
Removing Case From Shipping Skid and General Installation
CAUTION:
Do not push or pull against the top end glass, or
door frames and do not pull on end panels when removing the case
from the skid or moving the case. Case damage or glass breakage will result.
2.
Remove crate top and sides and note missing or damaged items as explained in the pre-installation
procedures outlined above.
8.
Move the case as near as possible to the final location and before removing it from the shipping skid.
9.
Remove the (4) brackets that secure the case to the shipping skid.
10.
Prepare cabinet according to Cabinet Mounting Counter Models instruction in next section that pertain
to your model.
11.
The counter cases are shipped with end glass removed and lifting handles are provided on each side of
case. Using lifting handles lift the case off of skid and into required position. Once case is placed into
position remove lifting handles and install end glass as described in End Glass Installation Section
12.
The counter top that the case is being placed on must be level for proper drainage of defrost condensate
to the condensate evaporator or pump.
13.
The case must be sealed to the counter using a NSF Listed Sealant.
Additional Parts Shipped with Unit.
Remove bubble wrap and packing material for all shelves and panels, brackets, etc. If it is necessary to
remove tape residue from plastic materials, use cleaning compounds recommended in the cleaning
section of this manual. Install panels and shelving as described proper section of this manual.
Cleaning
For initial setup, clean the case as outlined in the “Weekly Cleaning” section of this manual.