INITIAL STARTUP
After all the checks outlined in the installation section of this manual have been made, the case is ready to
be put into service. Turn on the Power at the breaker box and flip the Power Switch and Light Switch on
unit to the on position. Also ensure that the control is powered on as described above.
(Refrigerated Models Only)
At start up from a warm unit, it is recommended that the temperature control is set to a warmer setting,
such as 1. After the unit has gone through several cycles, adjust the control to a mid range setting, then to a
colder setting if necessary to maintain desired product temperature. Allow refrigerated models to run for at
least two hours before placing pre chilled product into unit
Placing Product into Case
After completing shelving installation as outlined in “Shelving Installation and Removal” section of
this manual you may begin placing product into the display case.
- Do not exceed 100 pounds of weight per shelf. Heavy product should be distributed evenly across
the entire shelving area.
- Determine desired shelving location and angle before placing product in case. Product must be
removed to readjust shelf location and angle.
(Refrigerated Models)
- Do not overhang the front shelves with product. Product may overhang rear of shelf, but allow a
minimum of 1-1/2” between product and rear door. Improper clearance in front and rear of shelf
will block the refrigerated airflow and could cause product loss.
-Do not block the slots along the front or rear of the case display pan. Covering these slots will
block the refrigerated airflow and could cause product loss.
-The display pan is removable for cleaning and can become dislodged in shipment. To ensure
proper airflow and performance of the case, make sure that the display pan is pushed completely
down into evaporation tub. Check that the pan is installed properly before placing product the
display pans.
-CASE SHOULD BE STOCKED WITH PRE-CHILLED PRODUCT
ONLY.
ATTENTION:
- This Federal refrigerated display case is designed to operate in a
maximum environment of 80 DEG. F and 55% relative humidity.
Exceeding these limits could cause poor case performance and
sweating of glass panels.