![Fayat Bomag CR 820 T Tier 4 Operating Instructions, Maintenance Instructions Download Page 94](http://html1.mh-extra.com/html/fayat/bomag-cr-820-t-tier-4/bomag-cr-820-t-tier-4_operating-instructions-maintenance-instructions_546860094.webp)
8 Emergency Procedures
Operations Manual
CR 820 T
Date May 2020
Page 8-2
Engine Start-up After Stall
Under certain conditions the engine could stall
while under load.
Attempting to restart the engine immediately after it
stalls could overload and damage the starter.
If the engine stalls under load, allow several min-
utes for the hydraulic system pressures to “leak
down” before trying to restart the engine.
Jump Starting/Charging Batteries
Batteries give off explosive hydrogen gas when
charging. Keep flame and sparks away from the
battery while jump-starting or charging.
It is critical that the last cable connected and the
first cable disconnected is the negative (-) cable.
Make the negative (-) cable connection as far away
from the battery as possible. Connecting and dis-
connecting jumper cables or a battery charger to
and from a battery could cause a spark and ignite
the hydrogen gas that is produced by the battery.
These pavers use a 12 Volt electrical system. When
jump starting or charging the paver, make sure to
use a 12 Volt power source.
Open the LH hood access door.
Connect the jumper cables to the power source.
Connect the positive (+) cable (1) to the positive
(+) battery terminal or power terminal on the hood
raise power pack motor.
Connect the negative (-) cable (2) to the paver
frame away from the battery. The negative (-) cable
should always be connected away from the battery.
As soon as the engine starts, remove the jumper
cables.
These pavers use a 12 Volt electrical system. When
jump starting or charging the paver, make sure to
use a 12 Volt power source.
Open the LH hood access door.
Connect the jumper cables to the power source.
Figure 8.1
- Batteries
Connect the positive (+) cable (1) to the positive (+)
battery terminal.
Connect the negative (-) cable (2) to the paver
frame away from the battery. The negative (-) cable
should always be connected away from the battery.
As soon as the engine starts, remove the jumper
cables.
Summary of Contents for Bomag CR 820 T Tier 4
Page 2: ...Intentionally Left Blank ...
Page 3: ...Table of Contents Date May 2020 Page 1 Operations Manual CR 820 T TABLE OF CONTENTS ...
Page 10: ...Table of Contents Operations Manual CR 820 T Date May 2020 Page 8 Intentionally Left Blank ...
Page 11: ...1 INTRODUCTION Date May 2020 Page 1 1 Operations Manual CR 820 T 1 INTRODUCTION ...
Page 16: ...1 INTRODUCTION Operations Manual CR 820 T Date May 2020 Page 1 6 Intentionally Left Blank ...
Page 17: ...2 Safety Date May 2020 Page 2 1 Operations Manual CR 820 T 2 SAFETY ...
Page 38: ...2 Safety Operations Manual CR 820 T Date May 2020 Page 2 22 Intentionally Left Blank ...
Page 39: ...3 Technical Data Date May 2020 Page 3 1 Operations Manual CR 820 T 3 TECHNICAL DATA ...
Page 41: ...4 Operator Controls Date May 2020 Page 4 1 Operations Manual CR 820 T 4 OPERATOR CONTROLS ...
Page 99: ...9 Maintenance Date May 2020 Page 9 1 Operations Manual CR 820 T 9 MAINTENANCE ...
Page 126: ...9 Maintenance Operations Manual CR 820 T Date May 2020 Page 9 28 Intentionally Left Blank ...
Page 127: ...10 Storage Date May 2020 Page 10 1 Operations Manual CR 820 T 10 STORAGE ...
Page 129: ...Intentionally Left Blank ...