![Fayat Group DYNAPAC CC224HF Instruction Manual Download Page 115](http://html1.mh-extra.com/html/fayat-group/dynapac-cc224hf/dynapac-cc224hf_instruction-manual_3739713115.webp)
Maintenance - Lubricants and symbols
4812159601_H.pdf
2021-01-14
Maintenance - Lubricants and symbols
Fluid volumes
Fluid volumes
Drum
Drum
- Drum CC224, CC2200
13 liters
13.7 qts
- Drum CC224, CC2200
13 liters
13.7 qts
- Drum CC324/384,
CC3200/3800
14 liters
14.8 qts
- Drum CC324/384,
CC3200/3800
14 liters
14.8 qts
- Drum gear
0,8 liters
0.85 qts
- Drum gear
0,8 liters
0.85 qts
Hydraulic reservoir
40 liters
42 qts
Hydraulic reservoir
40 liters
42 qts
Diesel engine, Cummins
Diesel engine, Cummins
- oil
7 liters
7.4 qts
- oil
7 liters
7.4 qts
- coolant, no cab
18,6 liters
19.7 qts
- coolant, no cab
18,6 liters
19.7 qts
- coolant, with cab
19,8 liters
20.9 qts
- coolant, with cab
19,8 liters
20.9 qts
Diesel engine, Deutz
Diesel engine, Deutz
- oil
8 liters
8.5 qts
- oil
8 liters
8.5 qts
- coolant, no cab
18,9 liters
20.0 qts
- coolant, no cab
18,9 liters
20.0 qts
- coolant, with cab
20,1 liters
21.2 qts
- coolant, with cab
20,1 liters
21.2 qts
Always use high-quality lubricants and the
amounts recommended. Too much grease or
oil can cause overheating, resulting in rapid
wear.
Always use high-quality lubricants and the
amounts recommended. Too much grease or
oil can cause overheating, resulting in rapid
wear.
Other fuel and lubricants are required when
operating in areas with extremely high or
extremely low ambient temperatures. See the
‘Special instructions’ chapter, or consult
Dynapac.
Other fuel and lubricants are required when
operating in areas with extremely high or
extremely low ambient temperatures. See the
‘Special instructions’ chapter, or consult
Dynapac.
ENGINE OIL
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac engine oil 200
P/N 4812161855 (5 liters),
P/N 4812161856 (20 liters)
ENGINE OIL
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac engine oil 200
P/N 4812161855 (5 liters),
P/N 4812161856 (20 liters)
HYDRAULIC FLUID
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac hydraulic 300
P/N 4812161868 (20 liters),
P/N 4812161869 (209
liters)
HYDRAULIC FLUID
Air temperature -15°C - +50°C
(5°F-122°F)
Dynapac hydraulic 300
P/N 4812161868 (20 liters),
P/N 4812161869 (209
liters)
Air temperature over +40°C
(104°F)
Shell Tellus S2 V100
Air temperature over +40°C
(104°F)
Shell Tellus S2 V100
BIOLOGICAL
HYDRAULIC FLUID,
PANOLIN
Air temperature -10°C - +35°C
(14°F-95°F)
When it leaves the factory, the
machine may be filled with
biologically degradable fluid.
The same type of fluid must be
used when changing or topping
up.
PANOLIN HLP Synth 46
(www.panolin.com)
BIOLOGICAL
HYDRAULIC FLUID,
PANOLIN
Air temperature -10°C - +35°C
(14°F-95°F)
When it leaves the factory, the
machine may be filled with
biologically degradable fluid.
The same type of fluid must be
used when changing or topping
up.
PANOLIN HLP Synth 46
(www.panolin.com)
103
Summary of Contents for DYNAPAC CC224HF
Page 2: ......
Page 16: ...Introduction 4812159601_H pdf 2021 01 14 4...
Page 24: ...Safety Optional 4812159601_H pdf 2021 01 14 12...
Page 28: ...Special instructions 4812159601_H pdf 2021 01 14 16...
Page 38: ...Technical specifications 4812159601_H pdf 2021 01 14 26...
Page 76: ...Machine description 4812159601_H pdf 2021 01 14 64...
Page 100: ...Operation 4812159601_H pdf 2021 01 14 88...
Page 122: ...Maintenance Maintenance schedule 4812159601_H pdf 2021 01 14 110...
Page 130: ...Maintenance 10h 4812159601_H pdf 2021 01 14 118...
Page 146: ...Maintenance 500h 4812159601_H pdf 2021 01 14 134...
Page 174: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden www dynapac com...