www.fastech.co.kr
57
Protection Function
11-3.Alarm Check and Release
If an alarm occurs, remove its cause and then release it. The alarm can be released as
follows. In case of alarms of which [Reset] column is indicated to 「invalid」, power must be
off prior to releasing the alarms
Alarm
No.
Alarm Name
Description
Reset
1
Overcurrent
1)Check the motor’s short-circuit (A, /A, B, /B)
2)Check the mechanical status such as parameter setting.
Valid
2
Overspeed
1)Check parameter setting, and abnormal operation of the
motor.
2)Check the speed command of upper controller(ex:PLC).
Valid
5
Overheat
1)Get down the ambient temperature or install a cooling fan.
2)Check the distance is over 50mm between drivers.
Valid
6
Over regenerative
voltage
1)In case of high-speed operation, check if the acceleration
or deceleration speed is low.
Valid
7
Motor connection 1)Check the connection status of drive and motor.
Invalid
12
ROM error
1)Contact to distributor.
Invalid
14
Drive voltage error 1)Check if power is supplied to the drive.
Invalid
50
Internal
communication
1) Power on the drive again.
Invalid
51,60 STEP ON failure
1) Pass the STEP ON command again.
2) Power on the drive again.
Valid
201
IP setting error
1) Set the last number of IP and Gateway differently.
2) If using the basic IP address, set the IP setting from 2 to
254.
Invalid
202
IP conflict
1) IP conflict with other drives (including other products), so
check the settings of each drive (including other products).
Invalid
Summary of Contents for Ezi-Step II Plus-E MINI
Page 1: ...Rev 02 User Manual Text...
Page 8: ...www fastech co kr Specifications of the Drive 8 Dimensions...
Page 11: ...www fastech co kr 11 Specifications Size of the Motor Motor Size...
Page 12: ...www fastech co kr Specifications Size of the Motor 12...
Page 16: ...www fastech co kr Configuration 16 Controller Configuration...
Page 17: ...www fastech co kr 17 Configuration External Wiring Diagram...
Page 61: ...www fastech co kr 61 Appendix Brake Installed Motor Specifications and Size...