www.fastech.co.kr
37
Operation
②
T
he user can click 「Pause」 at User Program(GUI) to temporarily stop operating. In this
case, click 「Pause」 again, and remaining operation will be executed again.
Position control Operation
To operate the motor by parameters set by User Program(GUI) or DLL program. (This is not
connected with PT operation.)
Once position control operation is started, PT operation command is overridden. Likewise,
while PT operation is executing, position control operation command is overridden.
The followings show parameters applied to position control operation. All position table
item values are overridden.
Parameter Name
Description
Range
Axis Max Speed
Constant operation speed after acceleration is finished
1~2,500,000[pps]
Axis Start Speed
Operation start speed before acceleration starts
1~35,000[pps]
Axis Acc Time
Required time until the motor reaches the axis max
speed from stop status
1~9,999[ms]
Axis Dec Time
Required time until the motor reaches from the axis max
speed to the stop status
1~9,999[ms]
Motion Dir
To select motion direction (CW or CCW)
0~1
Pulse per Revolution
Number of pulses per revolution.
The range of ‘Axis Max Speed’ parameter depends on
this value.
0~15
Teaching Function
Teaching can be executed by User Program(GUI) and control input signal.
For more information, refer to
「User Manual – Position Table Function」
.
Summary of Contents for Ezi-Step II Plus-E MINI
Page 1: ...Rev 02 User Manual Text...
Page 8: ...www fastech co kr Specifications of the Drive 8 Dimensions...
Page 11: ...www fastech co kr 11 Specifications Size of the Motor Motor Size...
Page 12: ...www fastech co kr Specifications Size of the Motor 12...
Page 16: ...www fastech co kr Configuration 16 Controller Configuration...
Page 17: ...www fastech co kr 17 Configuration External Wiring Diagram...
Page 61: ...www fastech co kr 61 Appendix Brake Installed Motor Specifications and Size...