www.fastech.co.kr
Control I/O Signal
24
Connect PNP type Input signal
Connect the ‘+24V external’ pin of drive to ‘GND’ of Controller.
2)Output Circuit
Output circuit power should be separately prepared. This may share input circuit power. In
this case, power capacity should add output power capacity to input power capacity.
Applied voltage and power capacity in the control output port are as follows.
·Applied voltage≤30V
·Electrified current≤15mA
Output