www.fastech.co.kr
External Name and Function Setting of Ezi-STEPⅡ Plus-E MINI
18
5.External Name and Function Setting of Ezi-STEPⅡ
Plus-E MINI
5-1.Appearance and Part Name
5-2.IP Address Selection Switch (SW1, SW2)
1)
It can be set from 1 to 254. Please set IP without overlapping.
“0”, “255” cannot be used for IP setting. Be sure to set it to “1~254”.
The default Gateway is 192.168.0.1. When the switch is set to "1", change Gateway.
Refer to the [Manual - User Program 2-4] section for the change method. If the IP
address and gateway are the same, Alarm (201 or 202) occurs.
It is recommended to use "2 ~ 254" for IP setting. (Default: SW1: 2, SW2: 0)
2)
Basic setting is “192.168.0.xxx”, and xxx are set by switch.
Ex.) In case of SW1 : 9, SW2 : 6
9 * 1 + 6 * 16 = 105
IP Address : 192.168.0.105 (7-Segment display : 69)
3) If set to switch as 255(FF), IP Address is set automatically.
Because it uses DHCP, IP address is set automatically only when using a router.
(Connect the Ethernet to Ethernet IN connector)
When connecting directly to the controller (PC/PLC), it needs to be sure to set the IP
Summary of Contents for Ezi-Step II Plus-E MINI
Page 1: ...Rev 02 User Manual Text...
Page 8: ...www fastech co kr Specifications of the Drive 8 Dimensions...
Page 11: ...www fastech co kr 11 Specifications Size of the Motor Motor Size...
Page 12: ...www fastech co kr Specifications Size of the Motor 12...
Page 16: ...www fastech co kr Configuration 16 Controller Configuration...
Page 17: ...www fastech co kr 17 Configuration External Wiring Diagram...
Page 61: ...www fastech co kr 61 Appendix Brake Installed Motor Specifications and Size...