www.fastech.co.kr
Control I/O Signal
32
13) JPT(Jump Position Table)
Start Input
To select motion pattern (position table number) to be subsequently executed according to
input signal conditions. The difference from Paragraph 12), 「‘JPT Input0~Input2 Input」, is:
1)
PT number to be jumped must be composed to 10XXX;
2)
Next motion is not executed until ‘JPT Start’ is set to [ON].
If ‘Wait Time’ value of PT data is more than ‘0’, the time lapses additionally and then next
motion is executed.
【Example】
PT 14 Data
PT No.
…
Wait
Time
JP Table No
JPT 0
JPT 1
JPT 2
14
…
500
10015
10115
10116