7.7
Logic Summaries and Flow Charts
Logic A
-
Logic A (automatic) is the most common setting. It automatically closes the gate
depending on the set pause time. This logic must be used in conjunction with the accessories:
Free Exit Sensor and Gate Timer.
Gate Status
Result of Termi-
nal 1 activation
Result of Termi-
nal 2 activation
Result of Termi-
nal 4 interruption
Result of Terminal
5 interruption
Result of Terminal
4&5 interrupted
simultaneous
Closed
Opens leaf and re
-
closes after pause
time
No effect
Open and in
pause before
re
-
closing
Re
-
loads pause time
No effect
Re
-
loads pause time
Closing
Re
-
opens leaf
No effect
Stops motion and reverses direction after
interruption
Opening
No effect
Reverses direction
of motion
No effect
Reverses direction
of motion
Stopped in
mid cycle
Closes the leaf
No effect
Logic S
-
Logic S (safety) is designed for higher control and accelerated levels of safety. By
triggering an opening device (i.e. push button, transmitter) the gate reverses directions preventing
foreseeable accidents.
Gate Status
Result of Termi-
nal 1 activation
Result of Termi-
nal 2 activation
Result of Termi-
nal 4 interruption
Result of Terminal
5 interruption
Result of Terminal
4&5 interrupted
simultaneous
Closed
Opens leaf and re
-
closes after pause
time
No effect
Open and in
pause before
re
-
closing
Re
-
closes the leaf
No effect
Closes after 5 seconds
Closing
Re
-
opens the leaf
No effect
Reverses direction of motion
Opening
Re
-
closes the leaf
Reverses direction
of motion
No effect
Reverses direction
of motion
Stopped in
mid cycle
Closes the leaf
No effect
Estate Swing