2.3
3.
For a Dual gate opener unit, charge the slave board by wiring it to the master
board terminal strip. [terminal 6 of the master
must
connect with the right side of
J2 on the slave and terminal 15 of the master
must
connect with the left side of
the slave] (fig 3)
NEVER CONNECT POWER FROM ANY SOURCE DIRECTLY TO
THE SLAVE BOARD. The slave board may ONLY be connected to the
Master control board.
Let the unit charge for 12 hours, after remove both the transformer power and the
battery. You can now proceed with the installation process.
Fig 3
Power from
Master ONLY
Dual Unit Slave Charging
Estate Swing