![FAAC DAAB EP104 Instruction Manual Download Page 47](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053047.webp)
47
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
• Limit switch, L channels
No.
Name
Range
Factory Setting Ref. page
L001
Choice of limit switch type for motor 1
0-3
0
0
Disabled
1
Encoder
2
Limit switch
3
Time
L002
Choice of limit switch type for motor 2
0-3
0
0
Disabled
1
Encoder
2
Limit switch
3
Time
L110
Position of motor 1, viewed from the motor side
(If L001 = 1)
0-2
0
0
Disabled
1
Left
2
Right
L111
Position readout for motor 1 (if L001 = 1)
000-360 degrees
L112
Limit for open position, motor 1 (if L001 = 1)
145-360 degrees
180
L113
Limit for closed position, motor 1 (if L001 = 1)
015-180 degrees
90
L120
Position of motor 2, viewed from the motor side
(If L0012 = 1)
0-2
0
0
Disabled
1
Left
2
Right
L121
Position readout for motor 2 (if L002 = 1)
000-360 degrees
L122
Limit for open position, motor 2 (if L002 = 1)
145-360 degrees
180
L123
Limit for closed position, motor 2 (if L002 = 1)
015-180 degrees
90
L211
Time readout for motor 1 (if L001 = 3)
00.1-99.9 sec
L212
Time setting, motor 1 (if L001 = 3)
00.1-99.9 sec
00.1
L221
Time readout for motor 2 (if L001 = 3)
00.1-99.9 sec
L222
Time setting, motor 2 (if L001 = 3)
00.1-99.9 sec
00.1
Summary of Contents for DAAB EP104