Programmable output 2
No.
Name
Range
Factory Setting Ref. page
o200
Function of output 2
0 - 4
1
0
Disabled
1
Position indicator/Movement/Warning Signal as configured in o210 – o222
2
Presence detection/Direction sensing Signal as configured in o291
3
Lock
4
Alarm output Signal as configured in o230 – o239
o210
Open position
0 - 1
0
0
Disabled
1
Constant signal
o211
Mid position
0 - 1
0
0
Disabled
1
Constant signal
o212
Closed position
0 - 1
1
0
Disabled
1
Constant signal
o213
Movement
0 - 3
0
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
o214
Delayed switch-off Switch off after the specified
time For example to switch off lighting a specified
time after closing
0.00-9.59min
0.00
o220
Warning time before start
0.00-9.59min
0.00
o221
Warning function in combination with o220
1 - 3
1
1
Constant signal before timed opening and automatic closing
2
Constant signal before close signal, timed opening and automatic closing
3
Constant signal before all signals
o222
Function during warning time
1 - 2
1
1
Output signal deactivated during warning
2
Output signal as configured in o210-o213
o230
Alarm if there is an error as configured in
o231-o239. The alarm is activated for at least the
time set in this channel.
0.00-9.59min
0.00
o231
Alarm for faulty safety edge. Time as in o230.
0 - 1
0
0
Constant signal
1
Active
o232
Alarm for error message in display
0 - 1
0
0
Constant signal
1
Active