![FAAC DAAB EP104 Instruction Manual Download Page 49](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053049.webp)
49
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
No.
Name
Range
Factory Setting Ref. page
o132
Alarm for error message in display
0 - 1
0
0
Disabled
1
Constant signal
o133
Alarm if stop circuit interrupted
0 - 1
0
0
Disabled
1
Constant signal
o134
Alarm if door open
0 - 1
0
0
Disabled
1
Constant signal
o135
Alarm if door is in mid position
0 - 1
0
0
Disabled
1
Constant signal
o136
Alarm if door is in closed position
0 - 1
0
0
Disabled
1
Constant signal
o137
Alarm if vehicle loop 1 is activated
0 - 1
0
0
Disabled
1
Constant signal
o138
Alarm if vehicle loop 2 is activated
0 - 1
0
0
Disabled
1
Constant signal
o139
Alarm if photocell interrupted
0 - 1
0
0
Disabled
1
Constant signal
o183
Inversion of contact function for output
1 - 2
1
1
Normally open, NO
2
Normally closed, NC
Summary of Contents for DAAB EP104