17
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
• Signal reference
Safety edge 1, closing movement (S.E1)
OUT
+
-
RS 485
+
-
24VDC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
24VDC
300mA
Safety edge 2, closing movement (S.E2)
Stop input 1
Stop input 2
Stop input 3
Limit switch open motor 1
Limit switch closed motor 1
Limit switch open motor 2
Limit switch closed motor 2
Programmable input 1
Programmable input 2
Programmable input 3
Programmable input 4
Programmable input 5
Programmable input 6
Input for photocell and external loop detector
Communication (interlock)
24VDC (max 300mA)
Connection points
12VDC (max 50mA)
Safety edge, opening movement (S.E3)
Shared limit switch, motor 1
Shared limit switch, motor 2
Shared programmable input 1 & 2
Shared programmable input 3 & 4
Shared programmable input 5 & 6
Output for self test
• Low current
!
The safety circuit, safety edge or limit switch must not be connected to, or used for, any other function. If signals from
the EP104 are needed, a separate output card must be used.
The connection instructions are the same for all types of application, but not all signals may be needed.
If stop signals are unused, the associated input signals must be jumpered on the terminal block, see "Signal reference".
!
Note that the 24 V for the stop circuit must not be combined with other 24 V circuits.