63
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Programmable input 4
No.
Name
Range
Factory Setting Ref. page
P400
Channels in programmable input 4
0 - 1
1
0
Disabled
1
Enabled
P460
Control function
0-5
0
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
P461
Type of control signal when activated
1 - 2
1
1
Pulse
2
Signal for as long as the input is activated
P462
Half operation
1 - 3
3
1
Half 1
2
Half 2
3
Halves 1 and 2
P463
Limited opening
0 - 1
0
0
Disabled
1
Timed opening based on the time specified in C412 and/or C414.
P470
Motor lock
0 - 1
0
0
Disabled
1
The barrier cannot be operated without a signal at programmable input 4. If the signal disappears the
barrier is stopped.
P480
Park
0 - 2
2
0
Disabled
1
Automatic closing disabled after the input is activated, reset by another control signal
2
Automatic closing disabled by a constant signal
P490
Interlock opening
0 - 1
0
0
Disabled
1
Opens the local door if P460 is set to open, and passes the signal on to the remote door
P496
Blocking disabled for local and remote doors. Only
works if there is a constant signal and P461 has the
value 2.
0 - 1
0
0
Disabled
1
Active
P498
Automatic closing disabled for remote door Only
works if there is a constant signal
0 - 1
0
0
Disabled
1
Active