![FAAC DAAB EP104 Instruction Manual Download Page 39](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053039.webp)
39
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
No.
Name
Range
Factory Setting Ref. page
C281
Power factor readout motor 2
0.00-0.99 cos
φ
Photocell
No.
Name
Range
Factory Setting Ref. page
C340
Safety function in closing movement
0 – 3
1
0
Disabled
1
Reversal to fully open
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
C341
Disconnection/blocking of photocell in closing
movement
0 - 2
0
0
Not blocked
1
Blocked if a limit switch is in the closed position
2
Blocked if both limit switches are in the closed position
C342
Safety function in opening movement
0 – 3
0
0
Disabled
1
Reversal to fully closed
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
C343
Check of external protection connected to PHOTO 0 - 1
1
0
No check
1
Test of protection connected to PHOTO
C351
PHOTO closing
0 – 1
0
0
Disabled
1
Enabled and subordinated to C340
C354
Type of closing with PHOTO
0 – 1
1
0
Close immediately if PHOTO is clear
1
Open first then close if PHOTO is clear
Summary of Contents for DAAB EP104