45
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Vehicle loop 2
No.
Name
Range
Factory Setting Ref. page
d200
Use loop 2
0 - 1
0
0
Input disabled
1
Input enabled
d201
Loop reading x1
000-999
d202
Loop reading x1000
00-99
d203
Activation from passing vehicle
000-999
d210
Detection limit for a vehicle in the loop
05-99
15
d211
Difference between on and off in the loop
00-50
03
d220
Loop presence reset
000 and 005-240min
120
d221
Fast loop presence reset
00-99 sec
00
d231
Compensation for the influence of the door half
operated by motor 1 on the loop in the close
position
00-50
03
d232
Compensation for the influence of the door half
operated by motor 2 on the loop in the close
position
00-50
03
d240
Safety function in closing movement
0 - 3
1
0
Disabled
1
Reversal
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
d241
Safety during run-on time in closing movement
0 - 1
1
0
Disabled
1
Enabled and subordinated to d240
d242
Safety function in opening movement
0 - 3
0
0
Disabled
1
Reversal to fully closed
2
Stop with automatic restart of automatic closing
3
Stop without automatic restart of automatic closing, wait for new control signal
d251
Loop closing
0 - 1
0
0
Disabled
1
Enabled
d254
Type of closing with loop
0 - 1
1
0
Close immediately when loop is clear
1
Open fully first, then close
d260
Control function
0 - 1
0
0
Disabled
1
Open
Summary of Contents for DAAB EP104