![FAAC DAAB EP104 Instruction Manual Download Page 69](http://html1.mh-extra.com/html/faac/daab-ep104/daab-ep104_instruction-manual_3107053069.webp)
69
Instruction manual version 1 for software version 4.04
INSTRUCTION MANUAL FOR DAAB EP104 CONTROL BOARD
Programmable wireless input 4
No.
Name
Range
Factory Setting Ref. page
r001
Readout of received wireless input
0 - 4
0
0
No wireless reception
1
Wireless input 1 is receiving a wireless signal
2
Wireless input 2 is receiving a wireless signal
3
Wireless input 3 is receiving a wireless signal
4
Wireless input 4 is receiving a wireless signal
r460
Operation
0 - 5
0
0
Disabled
1
Open
2
Close
3
Stop
4
Open/close
5
Open/stop/close
r462
Half operation
1 - 3
3
1
Half 1
2
Half 2
3
Half 1 and half 2
r463
Limited opening
0 - 1
0
0
Disabled
1
Timed opening
r470
Disable operation at wireless input 4.
0 - 6
0
0
Disabled, normal operation. (Programmable input has no function for wireless input 4)
1
Operate only if there is a signal at programmable input 1
2
Operate only if there is a signal at programmable input 2
3
Operate only if there is a signal at programmable input 3
4
Operate only if there is a signal at programmable input 4
5
Operate only if there is a signal at programmable input 5
6
Operate only if there is a signal at programmable input 6
r480
Park
0 - 1
0
0
Disabled
1
Park without automatic closing Reset by another control signal
r490
Interlock opening
0 - 1
0
0
Disabled
1
Sends a normal open signal to the remote door
Summary of Contents for DAAB EP104