SMX System MultiMatrix Switcher • SIS Configuration and Control
39
X1*
= Reclocker rates for SDI/HD-SDI
boards
00
= auto detect (default)
01
= bypass reclocker
X1(
= Signal status
0
= no signal at the input
1
= signal at the input (H)
2
= signal at the input (V)
3
= signal at the input (HV/receive link
presence for fiber boards)
X2)
= Output connection status
0
= no active connection on A or B
1
= first (A) port connected and second
(B) port not connected
2
= first (A) port not connected and
second (B) port connected
3
= active connection on both A and B
X2!
= Version number
x.xx.xxxx
(the first 3 numbers is the
version number and the last 4 is the
build number)
X2@
= Plane addresses
00
–
15
= for 16 planes
90
–
99
= for virtual planes (10 planes)
X2$
= Voltage
Positive or negative voltage magnitude
X2%
= Temperature
In Degrees Fahrenheit
X2^
= Fan speed
In RPM
X2(
= Create virtual plane address
90
–
99
= 10 planes
X3)
= Slot number
1
–
4
for 2U units
1
–
6
for 3U units
1
–
8
for 4U units
1
–
10
for 5U units
00
= e-mail F & P
1
–
10
= e-mail I