SMX System MultiMatrix Switcher • SIS Configuration and Control
53
Using the Command/Response Table for IP SIS Commands
The
Command and Response Table
begins on page 42.
Symbol Definitions
X5!
= Specific port number
01
–
99
00
= reserved
The port number is represented as two
ASCII characters (for example, port 05
would be represented as
30
35
in hex).
X5@
= GMT offset
–12.0
-
+14.0
Hours and minutes are removed from
GMT.
X5#
= On/Off status
0
= off or disabled
1
= on or enabled
X5$
= Unit name
Text string up to 24 characters (A-Z, 0-9,
and "-").
Not case sensitive.
NOTE:
The following characters are invalid or not recommended in the name:
~ , @
= ' [ ] { } < > ` " ; : | \ ?
and
space
The first character must be an alpha character, the last must not be a hyphen.
X5%
= Time and date (set and read)
MM/DD/YY•HH:MM:SS
MM
= month:
01
(January) through
12
(December)
DD
= day:
01
through
31
YY
= year:
00
through
99
HH
= hour:
00
through
23
MM
= minutes:
00
through
59
SS
= seconds:
00
through
59
X5^
= IP or gateway address
nnn.nnn.nnn.nnn
NOTE:
Factory default IP/Gateway address: 192.168.254.254
X5&
= E-mail domain name
Standard name conventions apply; for
example,
xxx.com
.
NOTES:
•
The following characters are invalid or not recommended in the name:
~ , @
= ' [ ] { } < > ` " ; : | \ ?
and
space
•
The @ character is acceptable only as lead-in to the domain name (such as
@
extron.com
)
X5*
= Hardware (MAC) address
xx-xx-xx-xx-xx-xx
X5(
= Default name
SMX-
xx-xx-xx
X6)
= Subnet mask
nnn.nnn.nnn.nnn
NOTE:
Leading zeros in each of the four fields are optional in setting values and
suppressed in returned values.