Troubleshooting a High Temperature
The internal temperature of the media player can be viewed on the front panel (see “
System
Status menu
“ in the “Operation” section. Temperatures above 85 °C (185 °F) indicate
an equipment cooling problem. Power off the media player and troubleshoot a high
temperature as follows:
1.
Verify that the room ambient temperature is lower than the specified 104 °F (+40 °C)
maximum.
2.
Check the front panel air filters and clean or replace if necessary (see “
Cleaning the Air
filters
“).
3.
Check that all cooling fans (one on the right and two on the left) are operating normally.
If the fans are not operating, or if you cannot find the cause of the overheating, contact
the Extron S3 Sales & Technical Support Hotline (see the
contact numbers
on the last
page of this guide for the Extron office nearest you.)
Battery Precautions
The JMP 9600 is provided with a permanently installed (factory-soldered in place) lithium
battery. The battery maintains the real time clock in the event of power failure or extended
storage periods and does not affect the normal operation of the player. If the battery
becomes ineffective, return the player to Extron for repair.
WARNING
:
There is a danger of explosion if battery is incorrectly replaced.
Do not attempt
to remove or replace the internal battery.
JMP 9600 Media Player • Mounting and Maintenance
104