DVS 605 • SIS Communication and Control
56
Command
ASCII Command
(host to scaler
)
Response
(scaler to host
)
Additional Description
Information request
General information
I/i
Vid
X!
•
Aud
X!
•V
typ
X#
•
Std
X1)
•
Blk
X3!
•
Hrt
X1#
•
Vrt
X1#
•
Pip
X!]
NOTES:
•
Aud
X!
response is a “-” on the non audio model. “Vtyp” returns the detected input type (
X!
*\).
•
Blk
X3!
response is “
0
” unless video is muted, then the response is “
1
”.
KEY:
X!
= Input selection:
1
to
5
X#
= Input video format:
0
= No signal detected (only valid for detected input format query, such as
X!
*\
),
1
= RGB,
2
= YUV Auto,
3
= RGBcvS,
4
= S-video,
5
= Composite,
6
= DVI/HDMI (Only available for inputs 3-5)
X1)
= Input standard:
0
= No signal detected (current input),
1
= NTSC 3.85,
2
= PAL,
3
= NTSC 4.43,
4
= SECAM
- = N/A (occurs when input is an active RBG, YUV Auto [but not NTSC/PAL], or HDMI signal)
X1#
= Horizontal and vertical frequencies (format is 3 digit with single decimal and leading zeros, for example,
075.3
)
X3!
= Video mute:
0
= off or disable,
1
= on or enable (mute to black)
Query firmware version
Q/q
x.xx
]
View firmware version.
Query full firmware
version
*Q/*q
x.xx.xxxx
]
View full firmware version details.
Query part number
N/n
zz-zzzz-zz
]
View part number.
View internal temperature
E
20STAT
}
Stat20
•
X1!]
Temperature in degrees Celsius.
KEY:
X1!
= Internal temperature (in degrees Celsius)
Backup/restore configuration
NOTE:
{config type} =
0
= IP config (ip.cfg),
2
= unit specific parameters (box.cfg),
The files are stored on directory /nortxe-backup created on the unit by the “save” commands.
Save device
configuration
E
1*
{config type}
XF
}
Cfg1*
{config type}
]
Save unit configuration to file system.
Restore device
configuration
E
0*
{config type}
XF
}
Cfg1*
{config type}
]
Restore unit configuration from file system.
Product naming
NOTE:
The 24 superscript shown below indicates that the user receives an E24 error on the device if the user is not logged in as
Administrator when trying to alter names.
Set unit name
24
EX1@
CN
}
Ipn
•
X1@]
Set unit name to
X1@
.
Set unit name to factory
default
24
E
•
CN
}
Ipn
•
X10)]
Set unit name to default
X10)
.
View unit name
E
CN
}
X1@]
View unit name.
KEY:
X1@
= Unit Name is a text string of up to 24 characters drawn from the alphabet (
A-Z
), digits (
0-9
), and the minus sign/
hyphen (
-
). The first character must be an alpha character. The last character must not be a minus. No blank or
space characters are permitted, and no distinction is made between upper and lowercase
X10)
= Default name: combination of model name and last three pairs of MAC address
(for example
DVS-605-Series-07-8C-EC
)
Summary of Contents for DVS 605
Page 6: ......