DVS 605 • Operation
33
Resetting the Unit
There are three unit reset modes (numbered 1, 4, and 5), These are available by pressing
the recessed
Reset
button on the rear panel with a pointed stylus, pen, or similar item to
access it. The following table gives a summary of the reset modes.
ATTENTION:
•
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or processor
reboot.
•
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du processeur.
NOTE:
The reset modes listed close all open IP and Telnet connections and sockets.
Each mode is a separate function, and not a continuation from mode 1 to mode 5.
DVS 605 Reset Mode Summary
Mode
Activation
Result
Purpose and Notes
Use Factory Firmwar
e
1
Hold in the recessed
Reset
button for
30 seconds while applying power to the
scaler.
NOTE:
After a mode 1 reset, update
the device with the latest firmware
version.
DO NOT
operate with the
firmware version that results from this
mode reset. This temporarily resets
the device to factory default until
power is recycled. To use factory
default firmware, upload that version
again.
The device reverts to the factory default
firmware.
•
Firmware reverts to the factory default
for a
single power cycle
.
•
All user files and settings (drivers, audio
and video adjustments, IP settings,
and so on) are maintained.
NOTE:
If you do not want to update
the firmware or perform a mode 1
reset by mistake, cycle power to
the device to return to the firmware
version running prior to the reset.
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Reset All IP
Settings
4
Hold down the
Reset
button until the
Reset LED blinks twice (approximately
6 seconds). Then, press
Reset
momentarily (<1 second).
IP settings revert to factory defaults.
•
Port mapping reverts to factory default.
•
DHCP turns off.
•
IP address is set to default address
(
192.168.254.254
).
•
Reset LED blinks four times in quick
succession during reset.
Use mode 4 to reset
all IP settings back to
factory defaults.
Reset to Factory Defaults
5
Hold down the
Reset
button until the
Power LED blinks 3 times (approximately
9 seconds). Then, press
Reset
momentarily (< 1 second).
The device reverts to the factory defaults
except for firmware.
•
Mode 4 results are performed.
•
All user modifiable configurations reset
to default values including IP settings
and real-time adjustments.
•
All user loaded files are deleted.
•
The Reset LED blinks 4 times in quick
succession during the reset
.
Use mode 5 to
restart with default
configuration (
)
.
NOTE:
This reset,
equivalent to the
E
ZQQQ
}
SIS
command, also
removes the initial
serial number
passwords and
sets them to no
password.