DVS 605 • Operation
27
Front Panel Lockout (Executive Modes)
To prevent accidental changes to settings, press the
Menu
and
Next
buttons simultaneously
for 2 seconds to enable front panel lockout mode (executive mode 2).
The menu system returns to the default menu within 10 seconds.
Executive mode 2
locks all front panel functions except input switching, PIP enable and
PIP swap, and Auto-Image.
Menu
and
Next
buttons and the
Adjust
knobs are disabled.
When executive mode 2 is active, all functions and adjustments can still be made through
USB, RS-232, or Ethernet control (see
page 34, for details on remote control).
To disable executive mode 2, press the
Menu
and
Next
buttons simultaneously for
2 seconds (see the flowchart in figure 23).
Menu
Press both for
2 seconds
Next
EXEC. MODE 2
ENABLED
Enable Executive Mode
EXEC. MODE 2
DISABLED
Disable Executive Mode
Menu
Press both for
2 seconds
Next
2
sec.
In RGBHV
#1 640x480
In 31.47 kHz
#1 59.94 Hz
Output
720p@60
3 sec.
timeout
3 sec.
timeout
Figure 23.
Front Panel Lockout
Executive mode 1
locks all front panel functions completely. This mode can be enabled
or disabled by SIS commands (see
Front panel security lockout (Executive Mode)
page 53), PCS (see
on page 90), or internal web pages (see
23
Summary of Contents for DVS 605
Page 6: ......