TOP Command
ExtremeWare 7.2e Installation and User Guide
331
To change the debug tracing facility for a certain system to a specified debug level, use the following
command:
configure debug-trace <system> <level> vlan <vlan name>
Some of the debug trace systems commands can be applied to a particular VLAN, some apply to the
switch as a whole, so the
vlan
option is not available with all systems.
To display the debug tracing configuration, use the following command:
show debug-trace <system> vlan <vlan name>
Again, the
vlan
option is not available with every system.
TOP Command
The
top
command is a utility that indicates CPU utilization by process.
System Odometer
Each field replaceable component contains a system odometer counter in EEPROM. You can use the
show switch
command to see how long an individual component has been in service since it was
manufactured.
Reboot Loop Protection
If the system reboots due to a failure that remains after the reboot, it reboots when it detects the failure
again. To protect against continuous reboot loops, you can configure reboot loop protection using the
following command:
configure reboot-loop-protection threshold <time-interval> <count>
If the switch reboots the specified number of times within the specified time interval, it stops rebooting
and comes up in minimal mode. If you reboot the switch manually or
run diagnostics
commands,
the time interval and count are both reset to 0.
Minimal Mode
In minimal mode, only the CPU, NVRAM, management port, and minimal tasks are active. The
following commands are supported in minimal mode:
•
reboot
•
unconfigure switch all
•
unconfigure switch
•
use image
•
use configuration
•
download bootrom
Summary of Contents for ExtremeWare 7.2e
Page 14: ...14 ExtremeWare 7 2 0 Software User Guide Contents...
Page 18: ...18 ExtremeWare 7 2e Installation and User Guide Preface...
Page 80: ...80 ExtremeWare 7 2e Installation and User Guide Accessing the Switch...
Page 102: ...102 ExtremeWare 7 2e Installation and User Guide Virtual LANs VLANs...
Page 108: ...108 ExtremeWare 7 2e Installation and User Guide Forwarding Database FDB...
Page 180: ...180 ExtremeWare 7 2e Installation and User Guide Security...
Page 194: ...194 ExtremeWare 7 2e Installation and User Guide Ethernet Automatic Protection Switching...
Page 218: ...218 ExtremeWare 7 2e Installation and User Guide Spanning Tree Protocol STP...
Page 248: ...248 ExtremeWare 7 2e Installation and User Guide Interior Gateway Protocols...
Page 256: ...256 ExtremeWare 7 2e Installation and User Guide IP Multicast Routing...
Page 308: ...308 ExtremeWare 7 2e Installation and User Guide Using ExtremeWare Vista on the Summit 400...
Page 316: ...316 ExtremeWare 7 2e Installation and User Guide Technical Specifications...
Page 324: ...324 ExtremeWare 7 2e Installation and User Guide Software Upgrade and Boot Options...