14
CAMT 20
14
Recommended separation distances between portable and mobile RF communications equipment and the CAMT
The CAMT is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. The customer or the
user of the CAMT can help prevent electromagnetic
The CAMT is intended for use in the electromagnetic environment in which radiated RF disturbances are controlled. The customer or the
user of the CAMT can help prevent electromagnetic interference by maintaining a miminum distance between portable and mobile RF
communications equipment (transmitters) and the CAMT as recommended below, according to the maximum output power of the
communication equipment.
Rated maximum
output power of
transmitter [W]
Separation distance according to frequency of transmitter [m]
150 kHz to 80 MHz outside ISM
and radio amateur bands *
150 kHz to 80 MHz
in ISM and radio
amateur bands *
80 MHz to 2700 MHz
(for define RF Wireless transmitters
see table before)
d = 0,35√P **
0,01
0,04
0,12
0,06
0,1
0,13
0,38
0,19
1
0,40
1,2
0,60
10
1,3
3,8
1,9
100
4,0
12
6,0
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres [m] can be
determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts [W] according to the transmitter manufacturer.
E =
P
6
d
*The ISM (industrial, scientific and medical) bands between 150 kHz and 80 MHz are 6.765 - 6.795 MHz, 13.553 - 13.567 MHz, 26.957 - 27.283 MHz and 40.66 - 40.7 MHz. The amateur
radio bands between 0.15 MHz and 80 MHz are 1.8 MHz - 2 MHz, 3.5 - 4.0 MHz, 5.3 - 5.4 MHz, 7 - 7.3 MHz, 10.1 - 10.15 MHz, 14 - 14.2 MHz, 18.07 - 18.17 MHz, 21.0 - 21.4 MHz, 24.89 -
24.99 MHz, 28.0 - 29.7 MHz and 50.0 - 54.0 MHz.
**Formulas coming from Ed.3 of the IEC 60601-1-2
2.8.2.2 Results and Deviations from
Standards and allowances used
Info about results, deviations see chapter 2.8.2.1. There are
no other deviation from the collateral standard.
2.8.2.3 Maintaining BASIC Safety and
Essential performance
Its mandatory to maintain the Linear actuator (and the con-
trol unit SCU) To save the essential performance for the ex-
pected Service life.
One time approved in the final application not change is al-
lowed due to the EMC influence.
NOTE
Do not change the once installed final application due to EMC
view.
WARNING
This product was tested against actual conditions of frequency
wireless environment present in Europe.
Summary of Contents for CAMT20
Page 1: ...CATEGORY MAX 2 LINES INSTALLATION OPERATION AND MAINTENANCE MANUAL CAMT20 Linear actuator...
Page 2: ......
Page 45: ......