22
CAMT 20
The 2 DOF rear bracket has the same 2 axis of rotation than
the front one (⮑ fig. 15).
It also comes fully assembled, adjusted to reduce the play to
a minimum and is, as standard, attached to the CAMT pro-
tection tube through 2 large pivot pins/bushings that define
the first axis of rotation.
Fig. 15
The rear bracket fits to the size of the outer tube of several
Ewellix telescopic pillars and it should be fastened using 6
standard M10 screws.
WARNING
Safety hazard caused by wrong attachment
The front bracket is designed for a direct attachment to the
following Ewellix telescopic pillars: CPMT, TLG and TLT.
However, it could also be attached to en adapter plate or a
support structure.
Detailed requirements like the tightening torque and the strangth
class are specified in chapter 6.4 Installation (⮑ page 32).
Disregard of the installation guide coud have serious impact to
safety and/or operation of the device.
4.4.5 U-Bracket
It is also possible to get a variant of the 1 DOF rear attach-
ment, the U-bracket (⮑ fig. 16).
In most cases, when the actuator is mounted centered on
the supporting pillar, it is advised to use a standard 1-DOF
bracket.
In some cases, when the actuator cannot be mounted cen-
tered on the pillar, the U-bracket can be used together with
an adaptor plate to be connected to the telescopic pillar.
Fig. 16
WARNING
Safety hazard caused by wrong attachment
Detailed requirements like the tightening torque and the strangth
class are specified in chapter 6.4 Installation (⮑ page 32).
Disregard of the installation guide coud have serious impact to
safety and/or operation of the device.