33
7.0 O p eration
7.0 Operation
7.1 Safety
WARNING
Risk of crushing
While moving onto solid objects, the force of the device may
cause injuries.
Therefore:
• Ensure that there are no person in the stroke area of the device
while in operation.
• Take note of maximun permissible operating data for the device
(refer to chapter 11.1 Technical data, page 42).
• Never tamper with the elements connected to the device while
the device is in operation.
CAUTION
Material damage due to static and dynamic overload of the
device
Static and dynamic overload can lead to damage and failure of
the device.
Therefore:
• Adhere to maximum permissible operating data for the device (re-
fer to chapter 11.1 Technical data, page 41).
• Never exceed nominal load.
• Never tamper with the elements that are connected to the device
while te device is in operation.
CAUTION
Actuator may be damage if liquids penetrate the actuator
during extension and retraction. Keep liquids away.
CAUTION
RIsk of injury through contact with the attachment adapter.
Therefore:
• Do not let objects or body parts come in contact with the fork
head of the actuator.
CAUTION
Material damage through overheating.
An overheating of the device can cause damage.
Therefore:
• Only use inegrated thermal switch
• Never exceed nominal load
• Always adhere to idle times and operating times (refer to chapter
⮑ 11.1 Tecnical data, page 41)
7.2 Turn on
NOTE
The device does not features ots own operating control
elements. The operation takes place via a separate operating
elements (=> Separate operating manual)
7.3 Turn off
NOTE
The device does not featores ots own operating control
elements. The operation takes place via a separate operating
elements (=> Separate operating manual)
7.4 Action before use
Perform an installation check before starting up the linear
actuator CAMT for the first time.
Installation check:
• All instructions from the above sections on ‘Operation’
have been followed.
• No side-acting forces impacting on the linear actuator.
• Fastening screws secured tightly.
• Entire stroke area unobstructed, so that the linear actuator
CAMT cannot be driven into a fixed object.
• All cables secured against pinching and trapping, and
properly connected.
• If connected with a flying leads cable, the leads are con-
nected in accordance with the wiring diagram in the ap-
pendix.
• Electrical supply secured and the linear actuator CAMT se-
curely connected to a control unit.
• Operating device connected to the control unit.
Summary of Contents for CAMT20