Appendix A
Instruction Manual ATS 400 with SC-NG
Version 4.03
65
Error number
Reason
Annotation
0xC4 – 0xC5
Relays should be switched
/ dropped, but not
recognized (Normally
closed)
Probably hardware failure of the relays in the
current enable circuit.
0xCB
No Slave - BB 1 + 2 have
switched - an error
occured
Probably hardware failure of the relays in the
current enable circuit.
0xCC
Relay state machine too
different for too long
0xCF
Main state machine too
long different
0xD0
MC1: in state D, UeK is
open, although door
opener is not actuated
Door opener not activated, but ÜK is open,
possibly wiring error.
0xD1
MC1: Interlock: Plausibility
error: UeK is closed when
the safety door is opened
(must not be)
Door (SK) is closed but guide lock (ÜK) is
open, possibly cabling error.
0xD2
MC1: Interlock-UeK
monitoring - cross-circuit
with E8
Door opener is energized but ÜK is still
closed, possibly wiring error.
0xD3
MC1: The loopback of O1
does not match
expectation
0xD4
MC1: At the start the door
opener must not be
activated yet.
0xD5
MC2: in state D, UeK is
open, although door
opener is not actuated
Door opener not activated, but ÜK is open,
possibly wiring error.
0xD6
MC2: Interlock:
Plausibility error: with
open protective door is
UeK closed (may be
Not to be)
Door (SK) is closed but tumbler (ÜK) is open,
possibly cabling error.
0xD7
MC2: Interlock-UeK
monitoring - cross-circuit
with E8
Door opener is energized but ÜK is still
closed, possibly wiring error.
0xD8
MC2: The loopback of O1
does not match
expectation
0xD9
MC2: At the start the door
opener must not be
activated yet.
0xE0
Data from the PIC door
opener only allowed in K7,
K8, K9 - violated here
Problem in the firmware of the baseboard.
0xE1
Data from the PIC - START
signal only allowed in K5 -
violated here
Problem in the firmware of the baseboard.
0xE2
Data from the PIC timeout There will be no data received from the
baseboard. Hardware defect in the
baseboard.
0xE3
Data from PIC - Frame
Error - Stop bit not HIGH