page 46
Smartrack User Manual
ETC Ltd
6.4.1 Checking line voltage
From the offline menu, select AC and press
enter
. The display alternates
between
L2
and the present rms voltage found on the phase two supply to
the rack, eg
220
.
a)
To exit, press
enter
. The display returns to the
AC
menu header,
press
▲
or
▼
, until the offline menu header
– – –
appears.
6.4.2 Setting the output voltage scale
For a full explanation of this function, see section 6.5.2
a)
From the offline menu, Select
CAL
, and press
enter
. The display
shows the present rms voltage set for 100% dimmer output, eg
220
.
b)
Use the
▲
and
▼
keys to change the rms voltage output scale, in
steps of one volt.
c)
Press
enter
to save the new value and exit to the offline menu.
6.4.3 Clearing configuration settings
a)
From the offline menu, select
CLr
, then press
enter
, to clear all
address, profile, speed and output voltage scale settings back to fac-
tory defaults.