d)
Select a new speed, using the
▲
and
▼
keys. The enter LED flashes,
indicating that the speed displayed is not that recorded for the select-
ed dimmer(s).
e)
Press
enter
to record or
dimmer
to return to dimmer mode without
changing the speed setting.
When ‘Dim-ALL’ is selected, the profile or speed displayed is for the first
dimmer only.
6.4. Offline mode
Smartrack's offline mode is intended for installers and service engineers, and has
a separate security level to user mode.
In offline mode, all dimmer levels received via DMX512 are set temporarily to
zero. Normal DMX512 operation will be resumed upon exiting offline mode.
Note that there is no timeout from offline mode. You have to exit in order to
return to normal operation.
In offline mode you can:
●
View rms voltage of the main supply
●
Set the output rms voltage scale for the rack
●
Clear down all configuration settings to factory defaults
To enter offline mode:
a) Access the control panel by pressing
enter
for three seconds.
b) Press the
▲
and
▼
keys together for one second. the offline symbol
– – –
is
displayed.
c) Using the
▲
and
▼
keys, scroll through the offline menu.
To leave offline mode:
a) Return to the offline menu.
b) Press the
▲
and
▼
keys together for one second. The control panel is
returned to user mode.