4.10.5 Connecting DMX input/output wiring
Route the DMX in and out wires to the signal terminals on the CPU cover
and trim to length. Terminate both the DMX in and out wires into the same
terminals.
4.10.6 Fitting blanking plates
Depending on the type of power assembly fitted in each position, one or
more blanking plates may need to be fitted to the inside of the front door.
All power assemblies without RCD protection are supplied with a blanking
plate. 5kW and 10kW power assemblies are also supplied with blanks,
to compensate for the smaller width required for their circuit breakers.
Where a power assembly position remains unused, you must fit a power
assembly blanking plate (part no 2000A1500).
To fit blanking plates:
a)
Offer blanking plate into position inside door.
b)
Using an M3 nut runner, remove the M3 nuts and washers from the
studs required to fit the blanking plates.
c)
Fit the blanking plate(s) in position, then replace and tighten the M3
washers and nuts.
Note: if Smartrack is only partially populated with power assemblies, then
blanking plugs must be fitted to unused outputs of the CPU board. These
are supplied with the power assembly blanking plate 2000A1500.
4.10.7 Closing the door
Check that all wiring is properly terminated and that no tools or other
items are left in the rack.
Swing door shut, and adjust line-up. Tighten three fixing screws.