page 41
Smartrack User Manual
Version 1.2
5.9.1 Setting response speed
a)
If the control panel is locked (enter LED off), press
enter
for three sec-
onds to gain access.
b)
Press
dimmer
to enter dimmer mode.
c)
Select all dimmers by pressing
▼
, or select an individual dimmer to
set with the
▲
and
▼
keys.
d)
Press
speed
to display the response speed menu, and scroll to the
desired speed for the selected dimmer(s), using the
▲
and
▼
keys.
The
enter
LED flashes, indicating that the speed displayed is not that
recorded in memory for the dimmer(s).
e)
Confirm the choice of response speed for the selected dimmer(s) by
pressing
enter
. This sets the control panel back to dimmer mode, for
the selection of the next dimmer to be set.
f)
To exit without saving, press
dimmer
or
profile
.
5.10 Important note – Exiting from the user interface
When exiting from the user interface, either following a press on
enter
or
Smartrack's automatic timeout, it is important that the rack should not be
switched off for at least 2 seconds. When returning to normal operation,
Smartrack sets a temporary response time of 2 seconds, so that any changes in
DMX levels will be implemented gently. If power is lost while this temporary
response time is being used, the next time Smartrack is switched on it will retain
a 2 second response speed, and show
02
in the display window.
If you do get stuck in this situation, simply go into user mode, select ALL dimmers,
and set the desired response speed, using the
▲
and
▼
keys.