10
Kongsberg XL
User Defined Reference Points
You can specify
User Defined Reference Points
.
User Defined Reference Points
are used if you want your job positioned in a fixed position on
the table (Rx), but not in the
Main Reference Point
(R).
A special version of
User Defined Reference Point
is the
Panel Reference Point
.
1
Position the
Laser Pointer
in the position where you want your
Panel
Reference Point
.
2
Press the
Set Reference Point
button on
Operators Panel
.
The
Panel Reference Point
is set to current
Laser Pointer Position
Rulers and Reference Points
The
Ruler System
ensures an easy and
correct positioning of the material on the
table.
The
Main Reference Point
shall be defined dr
= 10 mm/0.39 in. inside the ruler.
When you use the
Right Ruler
, the
Reference
Point
will automatically be moved to an
identical distance from the
Right Ruler
, as it is
defined from the
Left Ruler
.
The
Right Ruler
is normally used for
Reverse
Score
operations. At the same time the
direction of the X axis is reversed.
10.8.
Table Speed
Menu Bar
->
Advanced
->
Configure Tools
...->
Velocity X/Y
This is the default value for each
Tool
when
Layers
are created.
Opened Job
->
Edit Layer
->
Speed X/Y
Modify Speed for this particular Job.
Opened Job
->
Production Setup
->
Quality
Here you specify if this is a
High Quality Job
or
High Speed Job
.
51