18
Kongsberg XL
18. Frequently Asked Questions
18.1. Machine
My machine does not react when switching on
Please check electrical connection, do you have 230V? Is there enough compressed air, 7bar?
Check all main fuses in the MPU, see
Fuse Replacement
Check all connections at the MCU behind the control panel
Check all connections at the start up button and the emergency buttons:
Safety system won’t reset
Make sure all sensors are aligned correctly, check the black dots on the side of the traverse
Are all transmitters pointing correctly to their receiver? Check if the red light is shining on the
receiver. If necessary, adjust by bending the transmitter/receiver holder
During start up: X1/X2/Y servo error
This is probably caused by a defect in an amplifier board. Please contact Esko for technical
support
During start up: X1/X2/Y fuse error
Check the fuse of the motor
If problem persists, it is likely to be the amplifier board malfunctioning. Please contact Esko for
technical support
“Missing compressed air”
Check if you still have 7 bar at the MPU
Are the hoses not bending? Can the compressed air flow easily?
Do you hear air escaping? Check for leaks
Is the connection at the head leaking air or broken?
164