![Esko Kongsberg XL User Manual Download Page 33](http://html.mh-extra.com/html/esko/kongsberg-xl/kongsberg-xl_user-manual_2427111033.webp)
8
Kongsberg XL
This position was not reachable for all tools and cameras (depending upon tool head).
In order to run all tools properly, a limited work area was defined, using a separate
Reference
Point
.
In iPC
For MultiCUT, MultiCUT HP, PowerHead and FlexiHead with i-Camera
The
Main Reference Point
is defined to be in
Main Zero point 2
in the figure above.
Using this
Main Reference Point
, all tools and cameras will be available inside the
Limited
Work Area
.
If you want to run jobs using
Main Zero point 1
as your
Reference Point
, you should:
• Establish a
User Defined Reference Point
in position X=-20, Y=-80 mm from
Main
Reference Point
.
• Use this
User Defined Reference Point
as the
Reference Point
for your jobs.
• To simplify, prepare a
Production Preset
with correct settings. Reuse this
Production
Preset
for all actual jobs.
For all other tool heads on XL
33