Overview
VME-PMC-CADDY/2plus
Hardware-Manual • Doc.-No.: V.1915.23 / Rev. 1.0
Page 11 of 47
1.4 Technical Data
1.4.1 General Technical Data
VMEbus-Interface
IEEE 1014 / Rev. D
Master or Slave functionality
Base address
geographical addressing
Address modifier
standard supervisory and non-privileged data access,
extended supervisory and non-privileged data access,
short supervisory and non-privileged access
VMEbus access
- Legacy-protocols supporting the preservation of existing VME-
systems
- VME64 extensions
- 2eVME- and 2eSST protocols
VMEbus back plane
compatible to VME32, VME64 and VME64x back planes
Ambient temperature
range
Standard:
0...50
C
(order no.: V.1915.05)
Extended
temperature range:
-40...+75
C (order no.: V.1915.06)
Conduction cooled: -40...+75
C (order no.: V.1915.04)
Humidity
max. 90%, non-condensing
Connectors
P1, P2 -
160-pin VG-connector according to DIN 41612 in compliance
with VME64 extension
P0 -
95-pin I/O-connector according to IEC 1076-4-101
J11 to J24 - 64-pin PMC-socket connector:
J11, J12, J21, J22 -
PMC-address/data signals
J13, J23 -
PCI 64 signals
J14, J24 -
PMC I/O-signals
The following connectors are only equipped in the VME-PMC-
CADDY/2plus and VME-PMC-CADDY/2plus-T versions:
X1400 -
Dual port RJ45 connector - Gigabit Ethernet Ports 1 and 2
X1940 - 10-pin har-link socket: 2x serial (RS-232)
Service- and diagnostic connector:
X1800 - Socket connector 1x16: Debug CPU
X1801 - Socket connector 1x7: JTAG-TSI148
X2120 - Socket connector 1x7: JTAG-PCI
X2310 - Socket connector 1x6: ISP-ADU848
Dimensions
160 mm x 233 mm
Slot format
6 U high / 4 HP wide