ets-lindgren.com
EMControl Command Set
71
UH
Description:
Changes the upper limit of the device for horizontal polarity. The
specified value must be greater than the lower limit for horizontal
polarization and between
–999 and 999.
Devices:
Towers
Syntax:
UH [+/
–] XXX
+
: Optional for positive values
–
: Necessary for negative values
XXX
: Decimal value for the upper limit to be set in
centimeters. Leading zeroes are optional.
Response:
OK
, or an error (error number)
Example:
Write
sdUH 300\n
: Set horizontal polarity upper limit to 300 cm
See Also:
UH?
UH?
Description:
Queries the upper limit of the device for horizontal polarity. The
value returned is in XXX format. Negative values are preceded by
a
–
(minus sign).
Devices:
Towers
Syntax:
UH?
Response:
[
–]XXX
: Value of the upper limit for horizontal polarization in
centimeters
Example:
Write
sdUH?\n
: Query horizontal upper limit
Read response
Response is
300\n
: Horizontal polarity upper limit is 300 cm
See Also:
UH
Summary of Contents for ETS-Lindgren EMControl 7006-001
Page 1: ...Model 7006 001 EMControl Positioner Controller Plug In Card User Manual...
Page 8: ...viii ets lindgren com This page intentionally left blank...
Page 12: ...12 Introduction ets lindgren com This page intentionally left blank...
Page 16: ...16 Specifications ets lindgren com This page intentionally left blank...
Page 18: ...18 EMControl Plug In Card Installation ets lindgren com This page intentionally left blank...
Page 88: ...88 EMControl Command Set ets lindgren com This page intentionally left blank...
Page 90: ...90 Warranty ets lindgren com This page intentionally left blank...