3. Usage
44
Parameter No.
Meaning
Range
Default Value
Cooling and Heating Switch Judgment
Cooling and Heating Switch Judgment
3
3
0
0
4
4
20
Ambient Temp. To Start Heating
Ambient Temp. To Start Heating
5
5
25
25
Ambient Temp. To Start Cooling
Ambient Temp. To Start Cooling
100
-20 -20,
stands
for
invalid
100 (
)
Shifting Priority
6
7
20
10-31 (in
℃
)
Set Room Temperature
0(via. Ambient Temp.), 1
(via. External Signal)
0(via. Ambient Temp.), 1
(via. External Signal)
-1
43
)
0 -
(in
℃
-1
43
)
0 -
(in
℃
5 - 35 (in
℃
)
5 - 35 (in
℃
)
Meaning of each parameter
List of adjustable parameters in Temperature Parameter Setting menu:
0
1
2
Parameter No.
Meaning
Range
Default Value
5
2
2
0 - 10 (in
℃
)
0 - 10 (in
℃
)
0 - 10 (in
℃
)
Domestic Hot Water Restart Based
On Water ∆T
Heating Restarts Based On Water ∆T
Cooling Restarts Based On ∆T
If "Auto" mode (unit opeartion mode, set by press "M" button) is set, unit needs to switch between cooling and heating
automatically, either according to "ambient temperature" (parameter 3=0) or "external signal" (parameter 3=1).
If setting=
“
via. Ambient Temp.
”,
the
system
will
automatically
switch
between
cooling
and
heating
functions
,
based
on
the
outdoor
ambient
temperature
:
When Ambient temperature is lower than value set in parameter 4, unit
activate heating operation.When Ambient temperature is higher than value set in parameter 5, unit activate cooling
operation.
If setting="via. External Signal", an external room thermostat or central control system in the building can control the.
cooling or heating requirements by connecting it to the respective signal ports. The signals are simple 1-0 (on-off) signals
List of parameters
Parameter No.
Meaning
Range
Default Value
Domestic Hot Water Restart Based
On Water ∆T
0
5
0 - 10 (in
℃
)
2
0 - 10 (in
℃
)
Heating Restarts Based On Water ∆T
1
2
2
0 - 10 (in
℃
)
Cooling Restarts Based On ∆T
Domestic Hot Water Restart Based On ∆T:
After sanitary hot water is heated up to the set temperature, unit will stop sanitary hot water operation. It will activate
sanitary hot water operation after temperature drops "Hot Water Restart Based On Water ∆T" below set temperature.
Heating Restart Based On ∆T:
After house heating temperature is heated up to the set temperature, unit will stop heating operation. It will activate
heating operation after temperature drops "Hot Water Restart Based On ∆T" below set temperature.
Cool Restart Based On ∆T:
After house cooling temperature is cooled down to the set temperature, unit will stop cooling operation. It will activate
cooling operation after temperature increases "Hot Water Restart Based On ∆T" above set temperature.
20
Summary of Contents for AWH11-V5+
Page 2: ...2 ...
Page 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Page 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Page 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Page 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...