3. Usage
34
Item
Sub-menu
Unit Statue
Operation
Level
Default factory
settings
Advanced
Setting Group
Advanced
Setting Group
Installer
Installer
OFF
OFF
Advanced
Setting Group
Advanced
Setting Group
A
D
Unit Motorized 3-way valve
Switching Time
Heating Operation Motorized
3-way valve Direction
Installer
Installer
OFF
OFF
1 same as cooling
operation
120 sec
B
C
Anti-Legionella Set Temperature
Anti-Legionella Duration
Anti-Legionella Maximum
Allowable Working Duration
Anti-freezing Function
Anti-freezing Starting Ambient
Temperature--Primary
Anti-freezing Starting Ambient
Temperature--Secondary
Anti-freezing Ending Ambient
Temperature--Secondary
Anti-freezing Starting Water
Temperature--Secondary
Anti-freezing Ending Water
Temperature--Secondary
60
120 min.
1 (ON)
5°
2°
5°
2°
15°
Manual ON/OFF of Heater in Hot
Water Mode
Backup Heating Source For Hot
Water Mode
Priority Of Backup Heating Sources
For Hot Water Mode (Compared
With Unit Auxiliary Heater)
Temperature Increasement
Checking Duration in Hot Water
Mode
Maximum Allowable Set Water
Temperature in Heating Mode
Manual ON/OFF of Heater in
Heating Mode
Backup Heating Source For Heating
Mode
Priority Of Backup Heating Sources
For Heating Mode (Compared With
Unit Auxiliary Heater)
Accumulated Value between
operation time VS set temp.
for Heating Mode
0 (OFF)
0 (No)
0 (lower)
40
42
0 (OFF)
1 (Yes)
1 (Higher)
45
Heating Curve Function
Room Temp. Effect On Heating
Curve
1 (ON)
0 (OFF)
Page in
the menu
54
54
55
56
57
46
46
30 min.
Summary of Contents for AWH11-V5+
Page 2: ...2 ...
Page 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Page 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Page 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Page 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...