3. Usage
29
3.1 Introduction of wired controller
1
2
ON/OFF
MODE
Up-Regulation
Timer
Confirm
Down-Regulation
Symbol
Function
Explanation
Heating mode
Cooling mode
Shower
Water mode
Heat recovery
function
Actual set
temperature
Actual water
temperature
Quiet operation
Defrosting
Degrees in Celsius
of Fahreneit
Operation values
Auxillary heater
step 1 and step 2
Anti legionella
function
Working mode
When heating mode is selected, symbol is
shown in the display
When cooling mode is selected, symbol is
shown in the display
When shower water mode is selected,
symbol is shown in the display
When auxillary heater is connected and
activated, symbol is shown in the display
Increases the shower water temperature wirth
electric heater weekly to kill bacterias
Shows the actual water temperatdure in
according to units operation mode
Shows the actual set temperatdure in
according to units operation mode
Not available for this model
Lower the working speed of compressor
and fan motors in selected time periode
Deicing the outdoor unit evaporator when ice
is build up. (Self learning, not adjustable)
Shown when digits is correspondent with
temperatures
Shows selected temperature values when unit
is on or parameter setting values
Symbol
display when selected,
flickers when activated
shown in
Symbol
display when selected,
flickers when activated
shown in
Symbol
display when selected,
flickers when activated
shown in
Symbol flickers when step 1,
2 or both are "ON"
Symbol starts flickering when function
is "ON"
Always "ON" when unit is "Water Control"
Always "OFF" when unit is "Room Control"
Always "ON" when unit is "ON"
When activated this symbol is "ON"
When defrosting is activated this sumbol is
"ON". For dual compressor system: left
symbol = system 2, right symol = system 1.
When parameter setting is selected, values
are shown in accordance to the parameter
setting menu
Anti feezing
protection
Self
function to avoid freezing
when ambient temperature drops and unit is
in "OFF" mode. (Not adjustable)
protection
Constantly lights for primary anti-freezing
protection.
Flickers for secondary anti-freezing
protection.
Summary of Contents for AWH11-V5+
Page 2: ...2 ...
Page 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Page 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Page 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Page 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...