3. Usage
55
Anti-freezing function can be activated, to protect the unit from damage caused by water freezing inside the unit.
Note: If unit is out of power, or water circuit is blocked, anti-freezing protection will not function properly.
Anti
-
freezing
protection
doesn
'
t
means
the
anti
-
freezing
protection
for
all
water
system
in
the
house
.
Please
apply
other
necessary
anti
-
freezing
protections
in
your
house
,
to
protect
the
house
from
damage
caused
by
freezing
.
When unit is OFF and anti-freezing protection is valid, if ambient temperature is lower than the "Anti-freezing Starting
Ambient Temperature--Primary", unit activate primary anti-freezing protection. Circulation pump will be forced to work
occasionally.
When unit is OFF and anti-freezing protection is valid, if ambient temperature is lower than "Anti-freezing Starting
Ambient Temperature--Secondary", if water outlet temperature is lower than "Anti-freezing Starting Water
Temperature--Secondary", compresor will be forced to work, until water outlet temperature is higher than "Anti-freezing
Ending Water Temperature--Secondary", or ambient temperature is higher than "Anti-freezing Ending Ambient
Temperature--Secondary".
Anti-freezing Ending Water
Temperature--Secondary
5 - 20 (in
℃
)
B9
15
Anti-freezing Starting Water
Temperature--Secondary
0 - 10 (in
℃
)
2
B8
Anti-freezing Ending Ambient
Temperature--Secondary
5
0 - 10 (in
℃
)
B7
Anti-freezing Starting Ambient
Temperature--Secondary
2
0 - 4 (in
℃
)
B6
Anti-freezing Starting Ambient
Temperature--Primary
5 - 10 (in
℃
)
B5
5
Anti-freezing Function
B4
1
0(invalid), 1(valid)
Parameter No.
Meaning
Range
Default Value
【
】
Backup Heating
Group C
List of parameters
Parameter No.
Meaning
Range
Default Value
Manual ON/OFF of Heater in Hot
Water Mode
C1
0
0(invalid), 1(valid)
Backup Heating Source For Hot
Water Mode
0(no), 1(yes)
C2
0
Priority Of Backup Heating Sources
For Hot Water Mode (Compared
With Unit Auxiliary Heater)
0(lower), 1(higher)
C3
0
Temperature Increasement Checking
Duration in Hot Water Mode
C4
40
1 - 20(in minutes)
0 (not exceeds compressor
maximum allowable water
temperature), 40 - 65
(maximum allowable set
water temperature in
heating mode)
Maximum Allowable Set Water
Temperature in Heating Mode
C5
42
Manual ON/OFF of Heater in
Heating Mode
0
0(invalid), 1(valid)
C6
Backup Heating Source For
Heating Mode
C7
0(no), 1(yes)
1
Priority Of Backup Heating Sources
For Heating Mode (Compared With
Unit Auxiliary Heater)
C8
0(lower), 1(higher)
1
Accumulated Value between operation
time VS set temp. for Heating Mode
0 - 600
C9
45
Summary of Contents for AWH11-V5+
Page 2: ...2 ...
Page 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Page 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Page 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Page 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...