3. Usage
54
10 - 240 (in minutes)
B3
120
Anti-Legionella Maximum Allowable
Working Duration
Anti-freezing Function
B4
1
0(invalid), 1(valid)
Anti-freezing Starting Ambient
Temperature--Primary
5 - 10 (in
℃
)
B5
5
Anti-freezing Starting Ambient
Temperature--Secondary
2
0 - 4 (in
℃
)
B6
Anti-freezing Ending Ambient
Temperature--Secondary
B7
5
0 - 10 (in
℃
)
0 - 10 (in
℃
)
2
Anti-freezing Starting Water
Temperature--Secondary
B8
5 - 20 (in
℃
)
Anti-freezing Ending Water
Temperature--Secondary
B9
15
Parameter No.
Meaning
Range
Default Value
60 - 75 (in
℃)
B1
60
Anti-Legionella Set Temperature
Anti-Legionella Duration
10 - 60 (in minutes)
B2
30
10 - 240 (in minutes)
B3
120
Anti-Legionella Maximum Allowable
Working Duration
【
Anti-legionella and Anti-freezing
】
Group B
Parameter No.
Meaning
Range
Default Value
60 - 75 (in
℃)
Anti-Legionella Set Temperature
B1
60
Anti-Legionella Duration
10 - 60 (in minutes)
B2
30
If user uses sanitary hot water directly out from the hot water tank, for healthy purpose, it
’
s requested to heat up the
water inside the tank over 60
℃
(
please
refers
to
local
regulations
)
for
water
sanitization
once
a
week
.
Note: ON/OFF of this function can be set in "Basic Operation" level via parameter setting.
When this function is ON, if in 7*24 hours time period, unit has not reached the set water temperature for "anti
-
legionella
function
" (
set
in
Advanced
Menu
)
even
once
,
then
unit
will
activate
anti
-
legionella
operation
at
"
Anti
--
legionella
function
starting
time
".
Heat Pump will heat the water up to 58
℃
,
together with
Auxiliary
Heater
or
Hot
Water
Back
-
up
Heater
to
get
the
set
"
Anti
-
Legionella
Set
Temperature
",
and
keep
this
temperature
for
"
Anti
-
Legionella
Duration
"
time
,
Anti
-
Legionella
operation
is
finished
successfully
.
If after working over "Anti-Legionella Maximum Allowable Working Duration", Anti-Legionella operation still has not
finished successfully, unit will be forced to end Anti-Legionella operation.
Parameter No.
Meaning
Range
Default Value
0 (Alway ON), 1 - 600(With
power for the set time, in
seconds)
Unit Motorized 3-way valve
Switching Time
120
A8
0 (Same as Hot Water
Operation), 1(Same as
Cooling Operation)
Heating Operation Motorized 3-way
valve Direction
A9
1
Parameter A8 is used to set the type of the motorized 3-way valve used to switch the direction of water flow in different
working modes. If it is set to 0, it means two directions of the valve is controlled by "with" or "without" power. If it is set
to any
value
other
than
0,
it
means
the
valve
takes
this
time
to
switch
from
one
direction
fully
to
the
other
direction
.
In some special application, heating and hot water may use the same water circuit. In this way, one can set parameter A9
to 0, so unit has one water direction for both hot water and heating, and one direction for cooling only.
Summary of Contents for AWH11-V5+
Page 2: ...2 ...
Page 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Page 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Page 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Page 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...