2. Installation
24
5) Sensor cables
Take all sensors and communication cables out from the accessories bag. Connect the sensors together with
the quick connectors on communication cables. After done, insert communication cables (the end without
quick connector) that have no quick connector through cable gland, and connect them to the correspondent
terminals on terminal block.
A
TR-Room temperature sensor
B
TUP-Coil temperature sensor
TUI-Water inlet temperature sensor
Connect these sensors with communication
cables by quick connector, and then connect
communication cable (the end without quick
connector) with terminal block. (These
sensors are packed inside the accessories
bag).
TUP/TUI/TUO(terminal of indoor PCB
and outdoor sensor) are connected to the
terminal board, connect via cushion cable.
Place all sensors in right positions
Sensor cable connection
Indoor control
Communication cable
CO M
TUI
CO M
TUO
CO M
T UP
CO M
COM
TUI
COM
TUO
COM
TUP
COM
TC-water temperature sensor for cooling
TH-water temperature sensor for heating
TW-Water temperature sensor for hot water
Summary of Contents for AWH11-V5+
Page 2: ...2 ...
Page 8: ...1 3 2 Monoblock unit 1 Before use 8 AW9 V5 AW11 V5 ...
Page 75: ...Cable connected to fan motor capacitor 4 4 Maintenance 5 75 ...
Page 80: ...5 Attached drawing Monoblock unit AW9 V5 80 157 95 60 317 156 1065 754 693 1053 343 354 50 ...
Page 85: ...5 Attached drawing Monoblock unit AWH9 11 V5 85 ...