SAMPLE PLC PROGRAM
The sample program assumes one generic Ethernet IP module named EzMD, one 16-bit DC
input module named Local:1, and one 16-bit DC output module named Local:2.
Inputs and outputs assigned below.
The Ladder diagram, tags, and rung descriptions can be found on the pages that follow.
DC Inputs
Local:I.Data
DC Outputs
Local:O.Data
0
SetProduct #1 (momentary 24V)
0
MD Fault
1
Set Product #2 (momentary 24V)
1
MD Warning
2
Set Product #3 (momentary 24V)
2
MD Ready
3
3
MD Invalid
Command
4
Read Running Product (momentary 24V)
4
5
5
6
Select data to display
0V = Display running product
24V = Display heartbeat
6
7
7
No Reply from MD
8-14
8-14
7-bit Binary display
15
15
Ethernet Idle
PLC
91