5. Metal Detector status EzMD:I.Data[0] is updated approximately every second
and with every command exchange.
See the sample program rung 0.
B
IT
D
ESCRIPTION
V
ALUE
=1
V
ALUE
=0
0
metal detector fault
fault
no fault
1
metal detector warning
warning
no warning
2
metal detector ready
ready
not ready
3
invalid Ethernet command
invalid
valid
4
5
6
7
8
9
10
11
12
13
14
15
no reply from metal detector
no reply
reply
6. The Metal Detector increments a 16-bit counter (heartbeat) and sends it
back to the PLC EzMD:I.Data[5] with every status update .
See the Sample Program ladder diagram rung 1.
PLC
90