1. From the “Main Menu” select “I/O Setup” then “Input Configuration”.
2. Select the input that the photo-eye is wired to. Note: It is possible to use one photo-eye for
two functions (e.g., “Reject Index” and “Product Counter”); in this case, the photo-eye
must be wired to two inputs on the IOC circuit board (e.g., “In3” and “In4”).
3. Select “Product Counter” for the device function.
4. Enter a description if desired.
5. Set the debounce. In the vast majority of cases, the 2 mS default is sufficient.
6. Select “Active State” for the photo-eye. “Active State” is state when the product is in front
of the photo-eye. High = 10-30V Low = 0-0.9V
7. When the above steps are completed, the “Counters” block will be displayed on the home
screen. “Product” counts activations of the “Product Counter” input; “Reject” counts
actuations of the primary reject output.
8. Both counts can be cleared by pressing the button shown.